Stefano Sartori (Presenter)
Eureka srl - Lab Division
Bio: I got first degree in Biological Science in Padova University. Then I got a second degree in Clinical Biochemistry in florence University and last but not the list I got an award in Economic Science in Milan Ambrosetti School. Now I am the Managing Director of Eureka srl Lab Division , this company produces many kits ready to use for clinical applications regarding parmacological (TDM) and toxicological areas (confirmation test of drugs of abuse).
Authorship: S. Sartori, L. Motti
Alifax - Eureka lab Division
Short Abstract Alifax - Eureka Steroid Hormones in serum kit ready to use permits the simultaneous analisis of the most important steroids in a un single cromatography sample run (17-OH-Progesterone, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEAS), Androstenedione, Cortisol, 11-Deoxycortisol, Corticosterone, Aldosterone, Testosterone, Dihydrotestosterone, Androsterone, Estrone, Estradiol, Pregnenolone, 17-OH-Pregnenolone, Progesterone, 11-Deoxycorticosterone)after a simple matrix deproteinisation. To analyze correctly full panel in routine it's necessary to have a medium/high level mass QQQ detector coupled with an UHPLC. Seven levels of serum calibrators and two levels of serum controls are available, covering clinical range concentration values. |
Long Abstract
Alifax - Eureka Steroid Hormones in serum LC-MS/MS kit ready to use (CE/IVD) permits the simultaneous analisis of the most important steroids in a un single cromatography sample run (17-OH-Progesterone, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEAS), Androstenedione, Cortisol, 11-Deoxycortisol, Corticosterone, Aldosterone, Testosterone, Dihydrotestosterone, Androsterone, Estrone, Estradiol, Pregnenolone, 17-OH-Pregnenolone, Progesterone, 11-Deoxycorticosterone).
Matrix sample is deproteinized with an appropriate reagent containing deuterated internal standards (Cortisol d4,17-OH Progesterone d8,Aldosterone d7,Pregnenolone d4,Testosterone d3,Estradiol d5), centrifuged, evaporated, resuspended and injected into LC-MS/MS.
This method is simple, robust, sensitive and fast. Chromatography run lenghts is 6-7 minutes.
Calibration curve on 7 concentration levels is manufactered covering clinical Mass range, usually less than the lower limit and more than the higher level. Controls are 2 levels, low and high concentrations. Calibrators and Controls are serum lyophils.
Most of analites are simply detected with a medium LC-MS/MS systems but all of them are well analized (after the low limit of clinical range values) with high LC-MS/MS systems.
Three different kits are available, a part the unic 17 analites kit, covering three different panels/profiles (Glucocorticoids, Mineralcorticoids and Sexual hormones) using same column and same reagents.
Futures like simplicity, robustness and reproducibility obtained with this method make it a suitable kit to support the clinical laboratory routine.
References & Acknowledgements:
Description | Y/N | Source |
Grants | no | |
Salary | no | |
Board Member | no | |
Stock | no | |
Expenses | no |
IP Royalty: no
Planning to mention or discuss specific products or technology of the company(ies) listed above: | yes |